SINUMERIK 840D sl

30010 – Drive temperature

Drive temperature exceeded limit

Details

alarm

Error typeDrive temperature
MeaningInsufficient cooling overload continuous operation
Typical causesCheck cooling system allow drive to cool reduce load
Solutionsmedium

Catalog references

System Information

SINUMERIK 840D sl30010

Utilities

Troubleshooting Steps

Troubleshooting steps

medium

Other alarms

Other SINUMERIK 840D sl Alarms

FAQ

Common questions

How long to cool?

Typically 15-30 minutes depending on drive size